FiberTite® Roof Systems 1000 Venture Blvd. Wooster, OH 44691 800.927.8578 FiberTite.com Guide Specificatio FTR AD 01/21 General Guide Specification for the Installation of an Adhered FiberTite Roofing Systems FTR AD 01/21 is provided as a general foundation for the design and installation of a quality, high performance Adhered FiberTite Roofing System. Technical Bulletins, Application Guidelines and Best Practices are inclusive by reference and considered part of any specification intended to guide or govern the installation of any FiberTite Roofing System. PART 1 GENERAL 1.1 SECTION INCLUDES A. 1.2 Adhered Roofing Systems. (FTR-AD) RELATED SECTIONS A. Section 03300 - Cast-in-Place Concrete. (03 30 00 - Cast-in-Place Concrete.) B. Section 03510 - Cementitious Wood Fiber Decks. (03 51 13 - Cementitious Wood Fiber Decks.) C. Section 03520 - Composite Concrete Roof Insulation. (03 52 00 - Lightweight Concrete Roof Insulation.) D. Section 05311 - Steel Deck. (05 31 00 - Steel Decking.) E. Section 05360 - Composite Metal Decking. (053600 – Composite Metal Decking.) F. Section 06100 - Rough Carpentry. (06 10 00 - Rough Carpentry.) G. Section 07270 - Air Barriers. (07 27 00 - Air Barriers.) H. Section 07260 - Vapor Retarders. (07 26 00 - Vapor Retarders.) I. Section 07720 - Roof Accessories. (07 72 00 - Roof Accessories.) J. Section 07500 - Membrane Roofing. (07 50 00 - Membrane Roofing.) K. Section 07541 - Green Vegetated Roofing Systems.) (FTG-VRS) L. Section 07542 - Induction Welded Roofing Systems.) (FTR-IW) M. Section 07543 - Multi-Ply Roofing Systems.) (FTR-MP) N. Section 07544 -Mechanically-Attached Roofing Over Metal Roofing.) (FTR-MR) O. Section 07545 - Mechanically-Attached Roofing Systems.) (FTR-MA) P. Section 07546 - Ballasted Roofing Systems (FTR-BA) SeamanCorp.com | FiberTite.com FiberTite Roof Systems Guide Specification - FTR AD 01/21 | page 1 FiberTite Roof Systems Guide Specification – FTR AD 01/21 1.3 1.4 Q. Section 07548 - Simulated Metal Roofing Systems. (FTR-SMR) R. Section 07620 - Sheet Metal Flashing and Trim. (07 62 00 - Sheet Metal Flashing and Trim.) REFERENCES A. ASTM International (ASTM): 1. ASTM D6754 - Standard Specification for Ketone Ethylene Ester Based Sheet Roofing. 2. ASTM D312 - Standard Specification for Asphalt Used in Roofing. 3. ASTM D4601 - Standard Specification for Asphalt-Coated Glass Fiber Base Sheet Used in Roofing. 4. ASTM D4897 - Standard Specification for Asphalt-Coated Glass Fiber Venting Base Sheet Used in Roofing. 5. ASTM D 7654 - Standard Specification for Asphalt Used in Roofing Measured by Dynamic Shear Rheometer. 6. ASTM C 1289 - Standard Specification for Faced Rigid Cellular Polyisocyanurate Thermal Insulation Board. 7. ASTM C473 - Standard Test Methods for Physical Testing of Gypsum Panel Products. 8. ASTM D6163 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Glass Fiber Reinforcements. 9. ASTM D6164 - Standard Specification for Styrene Butadiene Styrene (SBS) Modified Bituminous Sheet Materials Using Polyester Reinforcements. B. American Society of Civil Engineers (ASCE): 1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures. C. FM Approvals (FM): 1. FM Standard 4470 - Single-Ply, Polymer-Modified Bitumen Sheet, Built-Up Roof (BUR) and Liquid Applied Roof Assemblies for use in Class 1 and Noncombustible Roof Deck Construction. 2. Loss Prevention Data Sheets 1-28, 1-29. D. FBC - Florida Building Code. E. Miami-Dade Building Code Compliance - N.O.A. (Notice of Acceptance). F. UL - Fire Resistance Directory. 1. UL-790 - Standard Test Method for Fire Tests of Roof Coverings. SUBMITTALS A. Submit under provisions of Section 01300 (01 30 00) - Administrative Requirements. B. Product Data: 1. Most recent published technical literature and guide specifications issued by FiberTite Technical Services (FTS). 2. Authorized Applicator’s approved copy of FiberTite Project Registration. 3. Preparation instructions and recommendations. 4. Storage and handling requirements and recommendations. 5. Typical installation methods. 6. Dimensioned shop drawings, including roof plan detailing perimeter enhancement, flashing methods, terminations and acceptance by FTS. 7. Written approval from FTS confirming any accessories submitted, not manufactured or expressly approved in FiberTite literature are acceptable and compatible with the proposed FiberTite Roofi
FTR-AD 01-21
Tips: Current document can only be previewed at most page3,If the total number of pages in the document exceeds page 3,please download the document。
Uploaded by admin on 2022-04-19 01:45:38